Non-contact thermometers -50…600/650°C
Description
Display of maximum and minimum temperature for the given measurement [MAX], [MIN] (YT-73200 / YT-73201)
Audible signal when high and low temperature are displayed ([Hi], [Low] YT-73200 / [HAL], [LAL] YT-73201)
Emissivity adjustment [EMS] (YT-73200 / YT-73201)
Ambient temperature display [AT] (YT-73200)
Alarm for operation at too low or too high ambient temperature - display of AH and AL respectively (YT-73200)
Instrument calibration [CAL] - ability to refine sensor readings in the range from -5.0 to + 5°C (YT-73200)
Display of the temperature difference result of the given measurement [DIF] (YT-73201)
Continuous temperature measurement function without holding the trigger [lock symbol] (YT-73201)
Storage of the last 100 measurements [LOG] (YT-73201)
Low battery display when voltage is below 2.5 V [battery symbol]
Automatic device shut-off after 7 seconds of inactivity (YT-73200) or 30 seconds of inactivity (YT-73201)
Body material ABS plastic
Operation at ambient temperature: 0°C-40°C
Emissivity is a parameter that determines an object's ability to emit thermal radiation. The emissivity coefficient of most organic, painted and oxidised materials is 0.95, and this is the factory-set parameter. However, some materials, such as lead or aluminium, have a much lower emissivity coefficient, so if a measurement as close as possible to the real value is needed, you must first set the emissivity coefficient parameter to a value suitable for the given material. Emissivity coefficient tables can be found in the scientific literature or on the Internet
Low and high temperature alarm - this function is useful, for example, when detecting thermal bridges on cold days. Measure the temperature at the centre of the wall to obtain a reference, then set the low-temperature alarm a few degrees lower depending on the outdoor temperature. The next step is to measure the temperature in places where thermal bridges most often occur, for example wall-to-ceiling junctions, around window frames, etc. If the temperature reading falls below the set alarm value, you will hear an audible signal and additional indication on the display.
Measurement accuracy - the optics and control electronics in YATO pyrometers provide high accuracy and repeatability of measurements. However, due to many variables beyond the manufacturer's control, including humidity and ambient temperature at the measurement locations, it is impossible to calibrate the device so that its accuracy is 100% under all conditions. The manufacturer states a possible measurement error of 2%, but not less than +-2°C at an ambient temperature of 0°C-40°C. This means that with the correct emissivity coefficient set, a measurement result of 100°C should be interpreted as a value in the range 102-98°C
Contents
Thermometer
Operating manual
Warranty card
AAA batteries 2 pcs
Verification is not included in the price Why?
Warranty for manufacturing defects, including measurement accuracy and successful passing of Uzstandart metrological verification: 12 months
Audible signal when high and low temperature are displayed ([Hi], [Low] YT-73200 / [HAL], [LAL] YT-73201)
Emissivity adjustment [EMS] (YT-73200 / YT-73201)
Ambient temperature display [AT] (YT-73200)
Alarm for operation at too low or too high ambient temperature - display of AH and AL respectively (YT-73200)
Instrument calibration [CAL] - ability to refine sensor readings in the range from -5.0 to + 5°C (YT-73200)
Display of the temperature difference result of the given measurement [DIF] (YT-73201)
Continuous temperature measurement function without holding the trigger [lock symbol] (YT-73201)
Storage of the last 100 measurements [LOG] (YT-73201)
Low battery display when voltage is below 2.5 V [battery symbol]
Automatic device shut-off after 7 seconds of inactivity (YT-73200) or 30 seconds of inactivity (YT-73201)
Body material ABS plastic
Operation at ambient temperature: 0°C-40°C
Emissivity is a parameter that determines an object's ability to emit thermal radiation. The emissivity coefficient of most organic, painted and oxidised materials is 0.95, and this is the factory-set parameter. However, some materials, such as lead or aluminium, have a much lower emissivity coefficient, so if a measurement as close as possible to the real value is needed, you must first set the emissivity coefficient parameter to a value suitable for the given material. Emissivity coefficient tables can be found in the scientific literature or on the Internet
Low and high temperature alarm - this function is useful, for example, when detecting thermal bridges on cold days. Measure the temperature at the centre of the wall to obtain a reference, then set the low-temperature alarm a few degrees lower depending on the outdoor temperature. The next step is to measure the temperature in places where thermal bridges most often occur, for example wall-to-ceiling junctions, around window frames, etc. If the temperature reading falls below the set alarm value, you will hear an audible signal and additional indication on the display.
Measurement accuracy - the optics and control electronics in YATO pyrometers provide high accuracy and repeatability of measurements. However, due to many variables beyond the manufacturer's control, including humidity and ambient temperature at the measurement locations, it is impossible to calibrate the device so that its accuracy is 100% under all conditions. The manufacturer states a possible measurement error of 2%, but not less than +-2°C at an ambient temperature of 0°C-40°C. This means that with the correct emissivity coefficient set, a measurement result of 100°C should be interpreted as a value in the range 102-98°C
Contents
Thermometer
Operating manual
Warranty card
AAA batteries 2 pcs
Verification is not included in the price Why?
Warranty for manufacturing defects, including measurement accuracy and successful passing of Uzstandart metrological verification: 12 months
Common specifications
| Emissivity | 0.10-1.00 (factory setting 0.95) |
| Temperature measurement: resolution, °C | 0,1 |
| Temperature measurement: accuracy, °C | t>0 ±1,5% или ±1,5°C t<0 ±3°C |
| Optical resolution | 1:12 |
| Power supply | 2x1,5 V AAA |
| Measuring speed, s | 0,5 |
| Spectral sensitivity, µm | 5-14 |
| Art. | Name | Price incl. VAT | Availability | Your order | Weight, kg | Dimensions, mm | Temperature measurement: range, °C |
|---|---|---|---|---|---|---|---|
| YT-73200 | Non-contact thermometer -50…600°C | 201 264 UZS | 10-25 pcs | 90x39x150 | -50 ~ +600 | ||
| YT-73201 | Non-contact thermometer -50…650°C | 361 872 UZS | 10-25 pcs | 0,2 | 108x49x177 | -50 ~ +650 |
Specifications
| Art. | Weight, kg | Dimensions, mm | Temperature measurement: range, °C |
|---|---|---|---|
| YT-73200 | 90x39x150 | -50 ~ +600 | |
| YT-73201 | 0,2 | 108x49x177 | -50 ~ +650 |
Other items in this section


