Clamp meters 1000 A 1000 V TrueRMS UT206B/UT207B/208B

Brand UNI-T (China)

Description

Differences between models:
UT206B - Basic model for AC networks:
- Measures AC current only. Cannot measure DC current
- Has thermocouple measurement from -40°C to +1000°C
- Supports connection of a flexible current loop sensor (iFlex) to extend the AC range to 3000 A

UT207B:
- Measures both AC and DC current up to 1000 A
- No thermocouple measurement
- Has a ZERO button to null residual magnetism readings before a DC measurement
- Does not support an external iFlex loop.

UT208B:
- Has all functions of UT206B and UT207B

Common measuring parameters for all models:
AC/DC voltage up to 1000 V
Resistance up to 60 MOhm
Capacitor capacitance up to 60 mF (60 000 µF)
Frequency from 10 Hz to 1 MHz
Duty cycle: from 10% to 90%
Maximum jaw opening 42 mm
Analogue bar graph 31 segments on the screen for tracking change dynamics.

LoZ mode lowers input resistance for effective elimination of induced ("ghost") voltage
Low-pass filter (LPF ACV) allows accurate voltage measurement on inverter and VFD outputs
Inrush Current up to 1000 A captures peak transient currents at start-up of powerful electric motors and compressors
Non-contact wiring detection (NCV) - built-in multi-segment detector with visual and audible alarm for finding live cables in walls and conduits

True RMS technology guarantees accurate readings with non-sinusoidal and heavily distorted AC signals
Display resolution 6000 counts
Automatic measuring range selection
Bright torch for illuminating the cable clamp zone in dark switchboards
Automatic screen backlight with ambient light sensor

Contents:
- instrument
- test leads
- case
- operating manual in English

Warranty for manufacturing defects, including measurement accuracy and successful passing of Uzstandart metrological verification: 12 months
Common specifications
AC voltage, V1000 ±1,2%
DC voltage, V1000 ±0,5%
Resistance60MΩ ±1%
AC current, A1000 ±2%
Art. Name Price incl. VAT Availability Your order
UT206BClamp meter 1000 A 1000 V TrueRMS with temperature measurement 1 248 016 UZS5 pcs
UT207BClamp meter 1000 A 1000 V TrueRMS 1 407 280 UZS2 pcsin transit 5 pcs(expected 12.11.2026)
UT208BClamp meter 1000 A 1000 V TrueRMS with temperature measurement 1 874 208 UZS4 pcs
Specifications
Art.Weight, kgTemperature, °CDC current, AFrequency, Hz
UT206B0,91-40~1000°C ±1%-50~60
UT207B0,88-1000 ±1,5%40~400
UT208B1,2-40~1000°C ±1%1000 ±1,5%40~400